Ir para o conteúdo principal
Ajuda

Versão atual de: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. '''230V AC input and 2 x 16.4V AC outputs''' {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
-''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing on which replacement transformer to get.''
+''The only problem is that the transformer’s output '''current rating''' (or power rating) is not specified as this would have a major bearing on which replacement transformer to get.''
Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) or Watts as this will tell you the current value as you know that the output voltage is 32.8V AC i.e. 2 x 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. '''230V AC input and 2 x 16.4V AC outputs''' {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing on which replacement transformer to get.''
-Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the output voltage is 32.8V AC i.e. 2 x 16.4V AC? VA = voltage x current.
+Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) or Watts as this will tell you the current value as you know that the output voltage is 32.8V AC i.e. 2 x 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
-Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. '''230V AC input and 32.8V AC output''' (2 x 16.4V AC outputs) {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
+Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. '''230V AC input and 2 x 16.4V AC outputs''' {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing on which replacement transformer to get.''
Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the output voltage is 32.8V AC i.e. 2 x 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
-Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 32.8V AC output (2 x 16.4V AC outputs) {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
+Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. '''230V AC input and 32.8V AC output''' (2 x 16.4V AC outputs) {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing on which replacement transformer to get.''
Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the output voltage is 32.8V AC i.e. 2 x 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
-Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 2 x 16.4V AC outputs {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
+Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 32.8V AC output (2 x 16.4V AC outputs) {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing on which replacement transformer to get.''
-Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the voltage is 16.4V AC? VA = voltage x current.
+Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the output voltage is 32.8V AC i.e. 2 x 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 2 x 16.4V AC outputs {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
-''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing what replacement transformer to get.''
+''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing on which replacement transformer to get.''
Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the voltage is 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 2 x 16.4V AC outputs {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
-''The only problem is that the transformer’s output current rating is not specified as this would have a major bearing what replacement transformer to get.''
+''The only problem is that the transformer’s output '''current rating''' is not specified as this would have a major bearing what replacement transformer to get.''
Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the voltage is 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Editado por: jayeff

Texto:

Hi,
-Here’s the [https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
+Here’s the [link|https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.
Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 2 x 16.4V AC outputs {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}
-The only problem is that the transformer’s output ''current rating'' is not specified as this would have a major bearing what replacement transformer to get.
+''The only problem is that the transformer’s output current rating is not specified as this would have a major bearing what replacement transformer to get.''
Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the voltage is 16.4V AC? VA = voltage x current.
The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.
Hopefully this is of some help.

Status:

open

Postagem original de: jayeff

Texto:

Hi,

Here’s the [https://elektrotanya.com/fender_frontman-15_frontman-15r_sm.pdf/download.html|service manual] for the amplifier. Be patient as it takes a little while to go from ''processing'' to ''Download'' after you have passed the security check and clicked on Go to Download '''''below''''' the Document preview box.

Looking at the schematic for the amp the 230V power transformer seems to have a 16.4V AC dual output centre tap secondary winding i.e. 230V AC input and 2 x 16.4V AC outputs {see TP1 (p5) and TP2 (p7) at circuit ref. C8 coming from ref. A7 at the transformer}

The only problem is that the transformer’s output ''current rating'' is not specified as this would have a major bearing what replacement transformer to get.

Is there any information printed on the transformer at all that might help e.g. something showing output VA (volt - amps) as this will tell you the current value as you know that the voltage is 16.4V AC? VA = voltage  x current.

The Fender part number for the 230V transformer is 031364 but I got no results at all when searching for the part using the part number. You may have better luck.

Hopefully this is of some help.

Status:

open