Linhas do passo

[title] Testing Sensor In Water
[* black] Wire a breadboard as shown in the picture to connect the particle photon to the sensor
-[* black] Important connections: GND is connected to negative rail and GND for sensor. 3V3 is connected to positive rail and vd,vdIO pins on sensor. A5 is connected to ___, A4 is connected to ____, A3 is connected to ____and A2 is connected to ____
-[* black] Test in cup of water to ensure it is water proof
+[* black] Important connections: GND is connected to negative rail and GND for sensor. The 3V3 is connected to the positive rail and the Vd, VdIO pins on sensor. A5 is connected to SDA, A4 is connected to SDO, A3 is connected to SCK and A2 is connected to CS.
+[* black] Place in a cup of water and monitor outputs to ensure that a water tight seal was achieved!