  1. Remove brush on top of device.
    • Remove brush on top of device.

  2. Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.
    • Remove the 12 mm T8 Torx screw from the bottom of the toothbrush. After removing the screw, pry off the base with a plastic opening tool.

  3. Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port. Be very careful not to damage the charging port during this step.  Otherwise you will have to solder this part back to the device as shown in the second figure.
    • Remove the internal electronic mechanism from the housing by prying the red clips shown in the figure. This removes the charging port.

    • Be very careful not to damage the charging port during this step. Otherwise you will have to solder this part back to the device as shown in the second figure.

  4. Free shipping on all orders over US$100,00 or containing a Pro Tech Toolkit!

    Visite Nossa Loja

    Ever fixed something? That’s Genius.

    Share your repair story with #ImAGenius

    We Are All Geniuses

    Share your repair story with #ImAGenius

  5. Next you will be able to remove the internal electronic mechanism as shown in the figure.
    • Next you will be able to remove the internal electronic mechanism as shown in the figure.

  6. Remove the white battery cover as shown in the figure.
    • Remove the white battery cover as shown in the figure.

  7. Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .
    • Remove the white circuit board cover as shown. This cover will require you to pry off the piece from the groves .

  8. Pry away the battery using an opening tool from the battery housing. This will break the circuit and avoid electric shock.
    • Pry away the battery using an opening tool from the battery housing. This will break the circuit and avoid electric shock.

  9. Desolder the circuit board from the motor as shown.
    • Desolder the circuit board from the motor as shown.

  10. Desolder the circuit board from the housing as shown to remove the board
    • Desolder the circuit board from the housing as shown to remove the board

Conclusão

To reassemble your device, follow these instructions in reverse order.

Uma outra pessoa concluiu este guia.

Jonathan Jarvis

Member since: 01-04-2016

452 reputação

4 Guides authored

Equipe

IUPUI, Team S6-G2, Baechle Fall 2017 Membro de IUPUI, Team S6-G2, Baechle Fall 2017

IUPUI-BAECHLE-F17S6G2

3 Membros

4 Guides authored

Visualizar Estatísticas:

Últimas 24 horas: 1

Últimos 7 dias: 4

Últimos 30 dias: 21

Todo: 260