Ir para o conteúdo principal

Alterações no passo nº 7

Edição por Elizabeth Eckes

Edição aprovada por Elizabeth Eckes

Antes
Depois
Sem alteração

Linhas do passo

-[* icon_caution] Verify the circuit board does not have any current supplied to it prior to performing next steps. If current is present, permanent damage to the multimeter is possible!
+[* icon_caution] Verify the circuit board does not have any current supplied to it prior to performing the next steps. If a current is present, permanent damage to the multimeter is possible!
[* black] Connect the black probe to the circuit board rail where one end of the solder bridge was.
[* black] Connect the red probe to the circuit board rail where the other end of the solder bridge was.
[* black] If the fix is successful, the multimeter should give a numerical readout on the multimeter screen. This means the rails are no longer connected.
[* icon_note] If the fix was unsuccessful, the multimeter should read "OL" on the screen, indicating an open circuit.