Alterações no passo nº 7
Edição por Curt Reitenbach —
Edição aprovada por Curt Reitenbach
- Antes
- Depois
- Sem alteração
Linhas do passo
[* black] Connect Multimeter to Repaired Solder Bridge. | |
- | [* |
+ | [* icon_note] Verify the circuit board does not have any current supplied to it prior to performing next step. |
[* black] Connect black probe to the circuit board where the solder bridge was. | |
[* black] Connect red probe to the circuit board above where the solder bridge was. | |
- | [* black] If the fix is successful, the multimeter should give a numerical reading on the screen. |
- | [* black] If the was unsuccessful, the multimeter should |
+ | [* black] If the fix is successful, the multimeter should give a numerical reading on the multimeter screen. |
+ | [* black] If the repair was unsuccessful, the multimeter should read "OL" on the screen, indicating an open circuit. |