-[* black] Connect red (positive) probe to the Voltage and Resistance Socket.
-[* black] Connect black (negative) probe to the Common/Ground Socket.
-[* black] Turn knob of multimeter to the Diode and Capacitance Test Setting.
-[* black] NOTE: Upon completing the steps above, the multimeter should read "OL" as shown in the picture.
-[* black] NOTE: Verify the circuit board does not have any current supplied to it.
+[* black] Setting up the multimeter:
+ [* black] Connect red (positive) probe to the Voltage and Resistance Socket.
+ [* black] Connect black (negative) probe to the Common/Ground Socket.
+ [* black] Turn knob of multimeter to the Diode and Capacitance Test Setting.
+ [* black] NOTE: Upon completing the steps above, the multimeter should read "OL" as shown in the picture.
+[* black] NOTE: Verify the circuit board does not have any current supplied to it prior to performing next step.
+[* black] Connect black probe to the circuit board where the solder bridge was.
+[* black] Connect red probe to the circuit board above where the solder bridge was.