Introdução

Occasionally the dryer may become too loud as a result of a faulty motor. This guide details the steps taken to replace the motor. Disassembly of the device requires a special bit for removal of tamper-proof screws.

  1. To change the motor, start by removing  the metal casing.
    • To change the motor, start by removing the metal casing.

    • Using the special bit, remove the large screws at the bottom of the casing.

    • To remove the case, lift the indicated spot with your hands.

    • The direction for turning the screws is different than what was indicated on the small sticker above the hole.

    Adicionar comentário

  2. Remove the three 1/2" Ph1 screws at the bottom of the red fan cap.
    • Remove the three 1/2" Ph1 screws at the bottom of the red fan cap.

    • Turn over the device.

    • Push the red tabs on the back of the unit with medium to heavy pressure, using a small prier.

    • Carefully remove the cap, to prevent damage to the sensor.

    Adicionar comentário

    • Remove both 3/8" Ph2 screws attached to the grey belt at the top and bottom.

    • Lift the grey belt away. This gives access to the server board.

    Adicionar comentário

  3. Spread Fixmas Cheer
    Get $12 off your purchase of $50 or more with code FIXMAS12
    Spread Fixmas Cheer
    Get $12 off your purchase of $50 or more with code FIXMAS12
    • Use a plastic opening tool to remove the two pink capped wires in the upper left corner of the server board.

    Adicionar comentário

    • Remove the brass nut from its bolt using a 10mm wrench.

    • Once the nut is free, disconnect the green wire.

    Adicionar comentário

    • Remove the rainbow ribbon cable using a plastic opening tool.

    • Remove the 1/2" Ph1 screw from the center of the circuit board.

    Adicionar comentário

    • Remove the four 3/4" Ph2 screws from the back of the device body.

    • Separate the motor housing from the device body.

    • Ensure that all wires connecting the motor housing and motherboard are disconnected before removing the component.

    Adicionar comentário

    • Remove the four 1/2" Ph2 screws from the filter.

    • Pull the filter plate away to reveal the motor.

    Adicionar comentário

    • Pull the motor out of the housing.

    • Be sure to feed the wires through the slot as you pull the motor out.

    Adicionar comentário

Conclusão

To reassemble your device, follow these instructions in reverse order.

Eli Forbes

Member since: 17-09-2018

169 reputação

Autoria de 1 guia

Equipe

Adicionar comentário

Visualizar Estatísticas:

Últimas 24 horas: 0

Últimos 7 dias: 6

Últimos 30 dias: 18

Todo: 39