The power switch connects the device motor to the power cord. If the power switch becomes broken or worn, the device may not function properly.

Remove the two 5.0 mm JIS #1 screws to loosen the cutting blades.
  • Remove the two 5.0 mm JIS #1 screws to loosen the cutting blades.

  • Make sure your device is not connected to power before you begin.

Adicionar comentário

Lift the bottom blade straight up from the device body to remove it.
  • Lift the bottom blade straight up from the device body to remove it.

Adicionar comentário

  • Remove the three 9.0 mm JIS #1 screws attaching the base of the blade assembly to the body.

Adicionar comentário

  • Lift the base of blade assembly straight up off of the body.

Adicionar comentário

  • Remove the two 12.0 mm JIS #1 screws on the back of the device body.

Adicionar comentário

  • Remove the 13.0 mm Phillips #2 screw on the side of the device body.

    • This screw is located on the opposite side of the body from the switch.

Adicionar comentário

  • Remove the spring on the side of the body using tweezers.

Adicionar comentário

  • Pry the body case off of the device using a spudger.

Adicionar comentário

  • Remove one 7.5 mm JIS #1 screw connecting the power cord to the switch base.

Adicionar comentário

  • Remove one 7.5 mm JIS #1 screw connecting the wire to the switch base.

Adicionar comentário

  • Remove the switch from device by lifting straight up from the device body.

Adicionar comentário

Conclusão

To reassemble your device, follow these instructions in reverse order.

Holly Dunn

Member since: 09-11-2017

101 reputação

Autoria de 1 guia

Equipe

IUPUI, Team S7-G3, Baechle Fall 2017 Membro de IUPUI, Team S7-G3, Baechle Fall 2017

IUPUI-BAECHLE-F17S7G3

3 Membros

4 Guides authored

Adicionar comentário

Visualizar Estatísticas:

Últimas 24 horas: 0

Últimos 7 dias: 0

Últimos 30 dias: 5

Todo: 79