Prereq only to remove the audio jack board with the lower case fully removed.

  1. Use a spudger to flip open the ZIF connector retaining flap for the dual microphone assembly ribbon cable. Use a spudger to flip open the ZIF connector retaining flap for the dual microphone assembly ribbon cable.
    • Use a spudger to flip open the ZIF connector retaining flap for the dual microphone assembly ribbon cable.

  2. Use tweezers to pull the  microphone assembly ribbon cable free of its connector. Use tweezers to pull the  microphone assembly ribbon cable free of its connector.
    • Use tweezers to pull the microphone assembly ribbon cable free of its connector.

  3. Remove the two 3.2 mm T5 Torx screws securing the audio jack board to the case.
    • Remove the two 3.2 mm T5 Torx screws securing the audio jack board to the case.

  4. Remove the audio jack board.
    • Remove the audio jack board.

Conclusão

To reassemble your device, follow these instructions in reverse order.