  1. Revlon 473 Hair Dryer Switch Replacement, Shell: passo 1, imagem 1 %32
    • Before disassembly, make sure that the device is unplugged.

    • Remove the two 17.83 mm black screws located on the handle.

  2. Revlon 473 Hair Dryer Switch Replacement: passo 2, imagem 1 %32
    • Separate the shell from the main component.

    • Check to ensure each piece is free from debris.

  3. Revlon 473 Hair Dryer Switch Replacement: passo 3, imagem 1 %32 Revlon 473 Hair Dryer Switch Replacement: passo 3, imagem 2 %32 Revlon 473 Hair Dryer Switch Replacement: passo 3, imagem 3 %32
    • Remove the casing from the heating element.

    • For reassembly, reattach the silver casing before the black cover.

  4. Revlon 473 Hair Dryer Switch Replacement, Switch: passo 4, imagem 1 %32
    • Locate the two switches in the handle of the device.

  5. Revlon 473 Hair Dryer Switch Replacement: passo 5, imagem 1 %32
    • Set the multimeter to 200 ACV.

  6. Revlon 473 Hair Dryer Switch Replacement: passo 6, imagem 1 %32
    • Bring the probes toward each switch to test for continuity.

    • If the numbers on the multimeter continue to change, the circuit is closed and the switches are functioning.

    • If the meter stays at a set number, the circuit is open, and the switch needs to be replaced.

    • To replace a faulty switch, cut the wires and solder the wires back on to the new switch.

Conclusão

To reassemble your device, follow these instructions in reverse order.

Uma outra pessoa concluiu este guia.

Jessica Leyva

Membro desde: 09/18/12

143 Reputação

Autoria de 5 guias

Equipe

Cal Poly, Team 1-5, Propen Fall 2012 Membro de Cal Poly, Team 1-5, Propen Fall 2012

CPSU-PROPEN-F12S1G5

Membros da 3

Autoria de 5 guias

0 comentários

Adicione um comentário

Exibir estatísticas:

Últimas 24 horas: 1

Últimos 7 dias: 7

Últimos 30 dias: 19

Duração total: 1,795