Ir para o conteúdo principal

Polaroid Automatic 100 Bellows Replacement

O que você precisa

  1. Polaroid Automatic 100 Bellows Replacement, Bellows: passo 1, imagem 1 %32 Polaroid Automatic 100 Bellows Replacement, Bellows: passo 1, imagem 2 %32 Polaroid Automatic 100 Bellows Replacement, Bellows: passo 1, imagem 3 %32
    • Fully extend the bellows by lifting the #1 lever.

    • Remove the camera cover in order to make the camera easier to work with.

    • When collapsing bellows, press down on the metal frame above the bellows.

  2. Polaroid Automatic 100 Bellows Replacement: passo 2, imagem 1 %32
    • Peel the two battery cable tabs off of the bellows.

  3. Polaroid Automatic 100 Bellows Replacement: passo 3, imagem 1 %32
    Ferramenta utilizada nesse passo:
    Flathead 3/32" or 2.5 mm Screwdriver
    $5.49
    Comprar
    • Remove one 15.5 mm flat head screw, with a 2.5 flathead screwdriver.

    • Remove two 2 mm flat head screws, with a 2.5 flathead screwdriver. Then carefully remove the cable cover.

    • Use the focus bar to extend bellows even further to access screws easier with the screwdriver.

  4. Polaroid Automatic 100 Bellows Replacement: passo 4, imagem 1 %32 Polaroid Automatic 100 Bellows Replacement: passo 4, imagem 2 %32
    • Open the back cover by pushing the lever on the bottom towards the left.

  5. Polaroid Automatic 100 Bellows Replacement: passo 5, imagem 1 %32
    • Remove the four 3 mm screws, which are attached to the lens of the camera, using a Phillips #0 screwdriver.

    • To make the screws easily accessible, close the bellows by pushing on the metal frame.

    • When reassembling, orient the camera so that screws are screwed in downward and stay in place.

  6. Polaroid Automatic 100 Bellows Replacement: passo 6, imagem 1 %32
    • Carefully use a classic wide metal spudger to bend the tabs of the bellows.

  7. Polaroid Automatic 100 Bellows Replacement: passo 7, imagem 1 %32 Polaroid Automatic 100 Bellows Replacement: passo 7, imagem 2 %32
    • Pull the bellow tabs back with long needle nose pliers.

    • Remove the bellows.

Conclusão

To reassemble your device, follow these instructions in reverse order.

2 outras pessoas executaram este guia.

Katie Miller

Membro desde: 04/14/15

680 Reputação

Autoria de 5 guias

Equipe

Cal Poly, Team 4-3, Maness Spring 2015 Membro de Cal Poly, Team 4-3, Maness Spring 2015

CPSU-MANESS-S15S4G3

Membros da 4

Autoria de 6 guias

0 comentários

Adicione um comentário

Exibir estatísticas:

Últimas 24 horas: 0

Últimos 7 dias: 2

Últimos 30 dias: 16

Duração total: 2,023