Ir para o conteúdo principal

Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement

O que você precisa

  1. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement, Diopter Adjustment Dial: passo 1, imagem 1 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement, Diopter Adjustment Dial: passo 1, imagem 2 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement, Diopter Adjustment Dial: passo 1, imagem 3 %32
    • Remove the four 4.6mm J000 Phillips screws from the sides and two 3.2mm J000 Phillips screws along the bottom.

  2. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 2, imagem 1 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 2, imagem 2 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 2, imagem 3 %32
    • Remove the two 3.2mm J000 Phillips screws located on the bottom edge of the viewfinder cover.

    • Carefully remove the viewfinder cover.

    • Remove the two 4.4mm J000 Phillips screws located near the top edge of the viewfinder.

  3. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 3, imagem 1 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 3, imagem 2 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 3, imagem 3 %32
    • Slide the Wide Plastic Opening Tool upwards along the underside of the rear casing.

    • Be careful not to disconnect the filament connections. Reinserting them can be difficult.

    • Slowly lower the casing into the position shown.

  4. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 4, imagem 1 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 4, imagem 2 %32
    • Use the Screwdriver J000 Phillips Head to remove the screw located at the lower-left corner of the face of the viewfinder glass.

    • Carefully lift the L-shaped clicker underneath the previously removed screw.

  5. Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 5, imagem 1 %32 Panasonic Lumix DMC-G5 Diopter Adjustment Dial Replacement: passo 5, imagem 2 %32
    • Slide the faulty diopter adjustment dial off the rod.

    • Replace the diopter dial with a 1-cm wheel.

Conclusão

To reassemble your device, follow these instructions in reverse order.

Uma outra pessoa concluiu este guia.

Equipe

USF Tampa, Team 1-3, Kass Spring 2017 Membro de USF Tampa, Team 1-3, Kass Spring 2017

USFT-KASS-S17S1G3

Membros da 4

Autoria de 6 guias

0 comentários

Adicione um comentário

Exibir estatísticas:

Últimas 24 horas: 0

Últimos 7 dias: 3

Últimos 30 dias: 10

Duração total: 1,020