  1. Ion Air Pro Record and Stop Switch Replacement, Record and Stop Switch: passo 1, imagem 1 %32
    • Remove the six screws (3 mm) that secure the lens cover bezel with a #00 Phillips screwdriver.

  2. Ion Air Pro Record and Stop Switch Replacement: passo 2, imagem 1 %32 Ion Air Pro Record and Stop Switch Replacement: passo 2, imagem 2 %32
    • Remove the blue securing the lens cover. Then simply pull off the lens cover itself.

  3. Ion Air Pro Record and Stop Switch Replacement: passo 3, imagem 1 %32
    • Remove black aluminum casing as shown.

  4. Ion Air Pro Record and Stop Switch Replacement: passo 4, imagem 1 %32
    • Using a #00 Phillips screwdriver, unscrew the screw securing the record/stop switch.

  5. Ion Air Pro Record and Stop Switch Replacement: passo 5, imagem 1 %32
    • Remove the record/stop switch. You are then able to replace the switch.

    • Be careful to not misplace the power button and spring that will no longer be secured when the switch is removed.

Conclusão

To reassemble your device, follow these instructions in reverse order.