Introdução

The control panel on the HP Officejet Pro 8600 plus may have touchscreen issues or display problems. This guide describes how to replace the control panel.

Peças

Não são necessárias peças.

  1. Lift the scanner lid to a resting position.
    • Lift the scanner lid to a resting position.

  2. Wedge the plastic opening tool into each of the three plugs to pry them from the control panel hinge located above the control panel screen.
    • Wedge the plastic opening tool into each of the three plugs to pry them from the control panel hinge located above the control panel screen.

  3. Remove the three 10mm-T10 Torx screws.
    • Remove the three 10mm-T10 Torx screws.

  4. Free shipping on all orders over US$100,00 or containing a Pro Tech Toolkit!

    Visite Nossa Loja
  5. Disconnect the control panel from the hinge by gently lifting upward, then outward towards you.
    • Disconnect the control panel from the hinge by gently lifting upward, then outward towards you.

  6. Detach the control panel from the black plastic latch by gently lifting upward, then outward towards you. Pull up on the left side when sliding up so the panel does not get stuck at the end of the track. Pull up on the left side when sliding up so the panel does not get stuck at the end of the track.
    • Detach the control panel from the black plastic latch by gently lifting upward, then outward towards you.

    • Pull up on the left side when sliding up so the panel does not get stuck at the end of the track.

  7. Turn over the control panel, making the screen face downwards. Place two fingers on the rectangular, plastic wire cover and squeeze inward.  Slide the cover downward, away from the cables, until the cover is fully removed. Place two fingers on the rectangular, plastic wire cover and squeeze inward.  Slide the cover downward, away from the cables, until the cover is fully removed.
    • Turn over the control panel, making the screen face downwards.

    • Place two fingers on the rectangular, plastic wire cover and squeeze inward. Slide the cover downward, away from the cables, until the cover is fully removed.

  8. Disconnect the two ribbon cables from the panel by pulling them upward out of their ports. This does not break the cables. They can easily be reconnected by plugging them into their ports again.
    • Disconnect the two ribbon cables from the panel by pulling them upward out of their ports.

    • This does not break the cables. They can easily be reconnected by plugging them into their ports again.

Conclusão

To reassemble your device, follow these instructions in reverse order.

Uma outra pessoa concluiu este guia.

Mackinnon Buck

Member since: 18-04-2018

466 reputação

3 Guides authored

Equipe

Cal Poly, Team S16-G4, Livingston Spring 2018 Membro de Cal Poly, Team S16-G4, Livingston Spring 2018

CPSU-LIVINGSTON-S18S16G4

4 Membros

5 Guides authored

Visualizar Estatísticas:

Últimas 24 horas: 4

Últimos 7 dias: 30

Últimos 30 dias: 135

Todo: 961