Ir para o conteúdo principal

Canary CAN100USBK Infrared Blocking Filter Replacement

O que você precisa

  1. Canary CAN100USBK Infrared Blocking Filter Replacement, Bottom Casing: passo 1, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement, Bottom Casing: passo 1, imagem 2 %32
    • Grip the rubber ring with your fingers and pull up.

    • Rotate the Canary as you pull out one tab at a time.

  2. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 2, imagem 1 %32
    • Use your Phillips #0 screwdriver to remove the four 6mm screws.

  3. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 3, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 3, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 3, imagem 3 %32
    • Use the flat end of the spudger to carefully pry off the bottom casing.

    • Alternate pushing up on the left and right sides until the clips holding the case in are visible.

  4. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 4, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 4, imagem 2 %32
    • Do not yank the bottom off or you may damage the ribbon cable or the ZIF connector.

    • Carefully remove the bottom casing by gripping it on both sides and pulling straight up.

  5. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 5, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 5, imagem 2 %32
    • Use the pointed end of the spudger to flip up the small retaining flap on the ZIF (zero insertion force) connector.

    • Pull the ribbon cable out towards the device.

  6. Canary CAN100USBK Infrared Blocking Filter Replacement, Front Panel: passo 6, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement, Front Panel: passo 6, imagem 2 %32
    • There are two empty nooks underneath the bottom of the panel close to each side of the case.

    • Place the pointed edge of the spudger in one of the nooks under the panel and pry upwards.

  7. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 7, imagem 1 %32
    • Adhesive will have to be reapplied after removing the panel.

    • Pull the panel away from the device.

  8. Canary CAN100USBK Infrared Blocking Filter Replacement, Top Casing: passo 8, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement, Top Casing: passo 8, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement, Top Casing: passo 8, imagem 3 %32
    • Use the flat end of the spudger to carefully pry off the top casing.

    • Alternate pushing up on the left and right sides until the inner clips are released.

    • Do not use too much force or the top may fly off unexpectedly.

  9. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 9, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 9, imagem 2 %32
    • Pull the top casing away from the device.

  10. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 10, imagem 1 %32
    • Use your Phillips #0 screwdriver to remove the two 5mm screws.

  11. Canary CAN100USBK Infrared Blocking Filter Replacement, Infrared LED Board: passo 11, imagem 1 %32
    • Using a Phillips #0 screwdriver, remove the six 6mm screws.

    • The seventh screw in the bottom middle is not connected to the motherboard and does not need to be removed.

    • As you remove the screws, hold on to the motherboard to prevent it from falling and sustaining damage.

  12. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 12, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 12, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 12, imagem 3 %32
    • Grip the circular part of the motherboard and pull it straight out of the device.

  13. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 13, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 13, imagem 2 %32
    • Do not pull on the wires themselves as they are fragile and may break from the connector.

    • Locate the power connector next to the lens protector on the infrared LED board. Using your fingers, wiggle the power connector back and forth until it is loose.

  14. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 14, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 14, imagem 2 %32
    • Find the power connector next to the buzzer that is labelled "MIC IR-LED". Use your fingers to wiggle it back and forth until it becomes loose.

  15. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 15, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 15, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 15, imagem 3 %32
    • Remove the four Phillips #0 6mm screws.

    • Lift the heatsink up and pull it away from the motherboard.

    • These screws also hold the infrared LED board in. Be sure to hold it while you remove the heatsink screws.

  16. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 16, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 16, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 16, imagem 3 %32
    • Lift the infrared LED board directly upwards and pull away from the motherboard.

  17. Canary CAN100USBK Infrared Blocking Filter Replacement, Lens Assembly: passo 17, imagem 1 %32
    • Remove the two Phillips #0 5mm screws.

    • Hold the lens assembly on the other side of the motherboard to prevent it from falling as you remove these screws.

  18. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 18, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 18, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 18, imagem 3 %32
    • Using your forefinger and thumb, grip the top and bottom of the lens assembly and pull away from the motherboard.

  19. Canary CAN100USBK Infrared Blocking Filter Replacement, Infrared Blocking Filter: passo 19, imagem 1 %32
    • Remove the Phillips #0 5mm screw.

    • The lens holder has two screw holes but the filter unit is held in with one screw. You are not missing a screw.

  20. Canary CAN100USBK Infrared Blocking Filter Replacement: passo 20, imagem 1 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 20, imagem 2 %32 Canary CAN100USBK Infrared Blocking Filter Replacement: passo 20, imagem 3 %32
    • Grab the battery end of the filter and pull to slide it out.

Conclusão

To reassemble your device, follow these instructions in reverse order.

Kristopher Gates

Membro desde: 02/28/17

399 Reputação

Autoria de 3 guias

Equipe

USF Tampa, Team S1-G2, Nance Spring 2017 Membro de USF Tampa, Team S1-G2, Nance Spring 2017

USFT-NANCE-S17S1G2

Membros da 4

Autoria de 16 guias

0 comentários

Adicione um comentário

Exibir estatísticas:

Últimas 24 horas: 0

Últimos 7 dias: 1

Últimos 30 dias: 4

Duração total: 409