Ir para o conteúdo principal

Bionaire BAP 600 Transformer Replacement

O que você precisa

  1. Bionaire BAP 600 Transformer Replacement, Control Board: passo 1, imagem 1 %32
    • Unplug 7 pin connector

  2. Bionaire BAP 600 Transformer Replacement: passo 2, imagem 1 %32
    • Unplug 2 pin wires which connects the front LED's.

  3. Bionaire BAP 600 Transformer Replacement: passo 3, imagem 1 %32 Bionaire BAP 600 Transformer Replacement: passo 3, imagem 2 %32
    • Remove two screws

  4. Bionaire BAP 600 Transformer Replacement: passo 4, imagem 1 %32
    • Unplug pins

    • Use scissors to cut zip ties

  5. Bionaire BAP 600 Transformer Replacement: passo 5, imagem 1 %32 Bionaire BAP 600 Transformer Replacement: passo 5, imagem 2 %32 Bionaire BAP 600 Transformer Replacement: passo 5, imagem 3 %32
    • Unplug rest of pin connections

    • Remove Neutral and Hot wires

    • They are the two black wires

    • Pull them out

  6. Bionaire BAP 600 Transformer Replacement: passo 6, imagem 1 %32 Bionaire BAP 600 Transformer Replacement: passo 6, imagem 2 %32 Bionaire BAP 600 Transformer Replacement: passo 6, imagem 3 %32
    • Unscrew two screws

    • Inspect capacitor for any bulges ( if it has a bulge , it means it is need to be replaced)

    • Check for burnt solder in the back of circuit board

  7. Bionaire BAP 600 Transformer Replacement, Transformer: passo 7, imagem 1 %32 Bionaire BAP 600 Transformer Replacement, Transformer: passo 7, imagem 2 %32
    • Use screwdriver to remove screws

Conclusão

To reassemble your device, follow these instructions in reverse order.

Alexander Tarancon

Membro desde: 10/12/16

49 Reputação

Autoria de 2 guias

Equipe

IUPUI, Team 4-4, Baechle Fall 2016 Membro de IUPUI, Team 4-4, Baechle Fall 2016

IUPUI-BAECHLE-F16S4G4

Membros da 5

Autoria de 7 guias

0 comentários

Adicione um comentário

Exibir estatísticas:

Últimas 24 horas: 1

Últimos 7 dias: 3

Últimos 30 dias: 7

Duração total: 198