Ir para o conteúdo principal

Why logic board chimes when pin is touched with probe?

Hello Guys,

Maybe one of you can help with this unusually weird problem I have with my 820-2330 logic board. The board powers on, but won't chime or boot until I touch a couple of specific pins on chip U8900. This is what happens exactly; when the board is powered on and I touch pins VO or OCSET on U8900 the board then chimes and boots normally. It is driving me crazy trying to figure this one out. At first I replaced U8900, then I replaced both FETS, then I replaced the Critical caps after the inductor all to no avail. Any help would be appreciated.

Thanks,

Roger

Responder a esta pergunta Também tenho esse problema

Esta é uma boa pergunta?

Pontuação 0
Adicionar um comentário

1 resposta

Look for an open trace or bad component attached to one or both of the pins you mentioned. If an input pin is not connected, touching it with a logic or scope probe connects it to ground through the probe circuit, thereby giving it a logic low (“0”)signal.

Esta resposta foi útil?

Pontuação 0
Adicionar um comentário

Adicionar a sua resposta

Roger será eternamente grato(a).
Exibir estatísticas:

Últimas 24 horas: 0

Últimos 7 dias: 0

Últimos 30 dias: 0

Duração total: 54