<?xml version="1.0" encoding="utf-8"?>
<rss version="2.0"
           xmlns:content="http://purl.org/rss/1.0/modules/content/"
           xmlns:wfw="http://wellformedweb.org/CommentAPI/"
          >
<channel>
<title><![CDATA[iFixit - Answers With Device &quot;Respiratory therapy&quot;]]></title>
<link>https://pt.ifixit.com/Answers/Device/Respiratory_therapy/All?rss=yes</link>
<description><![CDATA[Top Questions according to your query. Only showing &quot;Respiratory therapy&quot; questions.]]></description>
<language>en-US</language>
<pubDate>Wed, 19 Aug 2026 01:41:17 -0700</pubDate>
<item>
<title><![CDATA[ResMed AirSense 10: Why Does my Machine no longer records my nightly usage, it shows 2.3h]]></title>
<description><![CDATA[<p>Why does my CPAP M/C fail to record my actual usage after 8 hours it shows 2.38 hours of usage.</p>

<p>I am a long term user of CPAP and have never seen this is failure previously</p>

<p>⟐ Answer accepted agosto 11, 2026 at 0:22 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/967563/Why+Does+my+Machine+no+longer+records+my+nightly+usage,+it+shows+2.3h</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/967563</guid>
<pubDate>Tue, 11 Aug 2026 00:22:31 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: My unit is making a loud noise when I breathe in and out]]></title>
<description><![CDATA[<p>How can I fix the loud noise  when breathe in and out?</p>

<p>⟐ Answered agosto 09, 2026 at 3:28 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/718634/My+unit+is+making+a+loud+noise+when+I+breathe+in+and+out</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/718634</guid>
<pubDate>Sun, 09 Aug 2026 03:28:11 -0700</pubDate>
</item>
<item>
<title><![CDATA[Penlon AV-S: Why does my ventilator does not work according to my tidal volume?]]></title>
<description><![CDATA[<p>Why does my ventilator don't work according to the tidal volume set</p>

<p>⟐ Commented julho 23, 2026 at 9:41 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/965065/Why+does+my+ventilator+does+not+work+according+to+my+tidal+volume</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/965065</guid>
<pubDate>Thu, 23 Jul 2026 09:41:21 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: I need a firmware update]]></title>
<description><![CDATA[<p>How do I update the firware in my Airsense?  The internal modem is a 4G and I had to restore factory defaults and now it is back-leveled.</p>

<p>⟐ Answer edited julho 21, 2026 at 10:34 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/797368/I+need+a+firmware+update</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/797368</guid>
<pubDate>Tue, 21 Jul 2026 10:34:18 -0700</pubDate>
</item>
<item>
<title><![CDATA[SOMNOcomfort and SOMNObalance Ventilator: Parts for the equipment]]></title>
<description><![CDATA[<p>Where can I find a mask and pipe for this machine to purchase</p>

<p>⟐ Answered julho 21, 2026 at 2:40 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/964742/Parts+for+the+equipment</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/964742</guid>
<pubDate>Tue, 21 Jul 2026 02:40:19 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics Remstar Choice: Do you sell working units?]]></title>
<description><![CDATA[<p>Greetings,</p>

<p>Do you sell these models?<br />I have one now and want to get a spare and a second unit.<br />If so, what do you charge ?<br /><br /></p>

<p>⟐ Answered julho 02, 2026 at 9:23 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/962228/Do+you+sell+working+units</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/962228</guid>
<pubDate>Thu, 02 Jul 2026 09:23:35 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics EverFlo: How do I get a broken wheel off my concentrator]]></title>
<description><![CDATA[<p>How to replace broken caster</p>

<p>⟐ Answered maio 26, 2026 at 18:34 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/956916/How+do+I+get+a+broken+wheel+off+my+concentrator</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/956916</guid>
<pubDate>Tue, 26 May 2026 18:34:49 -0700</pubDate>
</item>
<item>
<title><![CDATA[Philips Respironics System One Dorma: Can I recalibrate SD card for pressure?]]></title>
<description><![CDATA[<p>Is it possible to recalibrate the pressure of my machine without a doctors prescription?</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/956371/Can+I+recalibrate+SD+card+for+pressure</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/956371</guid>
<pubDate>Sat, 23 May 2026 11:49:01 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics RemStar LX: Phillips Respironics Replacement Blower...]]></title>
<description><![CDATA[<p>I have a Phillips Respironics REMstar LX, Model 1000920, Serial #1444891, for which I need a Blower Assembly Kit, #622115.  Where/from whom may I find this part?  Thanks in advance.</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/954236/Phillips+Respironics+Replacement+Blower...</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/954236</guid>
<pubDate>Sun, 10 May 2026 06:29:49 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics Dreamstation: Power range is increasing while I am laying down and not sleep.]]></title>
<description><![CDATA[<p>The power range is increasing while I am awake. It will not stay at its level when I am just laying down and not sleep. What do I do to stop the pressure from increasing?</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/953421/Power+range+is+increasing+while+I+am+laying+down+and+not+sleep.</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/953421</guid>
<pubDate>Mon, 04 May 2026 11:00:01 -0700</pubDate>
</item>
<item>
<title><![CDATA[VersaMed iVent 201: O2 calibration with new sensor won´t update O2 sensor alarm message]]></title>
<description><![CDATA[<p>Hello,</p>

<p>I´ve trying to perform several O2 calibrations with a new sensor Max-16HT, however upon correct completion and saving the calibration the O2 sensor alarm message is still displayed on the left corner of the status bar, showing “O2 Sensor.” After that I tried performing a series of VVT’s but the only failure in this test is O2 100% (Failed), everything else is showing the result OK.</p>

<div class="imageBox imageBox_left"><img src="https://guide-images.cdn.ifixit.com/igi/s6CJm3n5ivL1Fc6X.standard" width="282" height="26" class="hasMenu hasLarge" alt="Imagem" onclick="window.open(&quot;https:\/\/guide-images.cdn.ifixit.com\/igi\/s6CJm3n5ivL1Fc6X.full&quot;, '', 'width=602,height=55')" /></div>

<p>Any clues or ideas on what may be happening will be greatly appreciated.</p>

<p>Thanks.</p>

<p>David</p>

<p><br /></p>

<p><br /></p>

<p>⟐ Answer edited abril 25, 2026 at 3:50 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/634671/O2+calibration+with+new+sensor+won%C2%B4t+update+O2+sensor+alarm+message</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/634671</guid>
<pubDate>Sat, 25 Apr 2026 03:50:19 -0700</pubDate>
</item>
<item>
<title><![CDATA[IMT Bellavista 1000: need the neonatal software for ventilator]]></title>
<description><![CDATA[<p>question  how to get neonatal software to install in ventilator</p>

<p>⟐ Answered abril 23, 2026 at 0:06 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/951609/need+the+neonatal+software+for+ventilator</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/951609</guid>
<pubDate>Thu, 23 Apr 2026 00:06:04 -0700</pubDate>
</item>
<item>
<title><![CDATA[Perfecto 2 Oxygen Concentrator: unit shuts down after 30 seconds]]></title>
<description><![CDATA[<p>unit shuts down after 30 seconds and has a flashing red light and a green light in sequence</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/944865/unit+shuts+down+after+30+seconds</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/944865</guid>
<pubDate>Fri, 13 Mar 2026 21:57:56 -0700</pubDate>
</item>
<item>
<title><![CDATA[Respironics CPAP: Relentless reboots, but runs fine once started.]]></title>
<description><![CDATA[<p>Worked fine originally after receiving donated used unit. After a few months, pushing the start button would beep, display logo, display FW version, display flow rate, spin up the blower, then go dark and start the cycle over.</p>

<p>Eventually, the blower stays on and it runs through my sleep cycle like nothing ever happened. This normal state might be reached after 20 restarts. Also, after some random restart count it will stay off, requiring a replug power-up to begin the restart cycle anew, up to three replugs and about 20min being a worst case. Best case it fires up after about 10 restarts. <strong>I just realized I've never checked the display before a replug so I'll do that tonight. I checked, it goes blank when it's all beeped out.</strong></p>

<p>All functions, settings, and input buttons work as expected after running, including the humidifier. No leaks or bad gaskets, blower spins freely. About to replace PCA button battery but the old one had good voltage. Contact cleaner used when resetting every jack. Power supply good. Filters clean. I'll be rechecking all of these things one more time plus a picky board inspection, but I don't expect to find a problem at component level.</p>

<p>I can't imagine what kind of consistent, repeatable error could exist with no fault found. It behaves as if some sensor feedback is telling the algorithm that it can't run or start. Considering getting a serial adapter module and downloading the tech software but I have never seen an error code on the display.</p>

<p>Subjectively, 3 things I find interesting are:</p>

<p>1) the restart blower puff seems to gain volume and power up to the running state; if it dwindles or remains lame it's likely restart attempts will stop until a replug</p>

<p>2) dial digit 4 is slightly dim, but lights as expected</p>

<p>3) I checked the button battery voltage in situ, and it crept upwards. I've never seen this before but some reading tells me their may be an intentional capacitor storage, maybe to kick start the blower or something.</p>

<p>I could talk about this all night, given that a new machine will run me $1400CDN.</p>

<p>⟐ Commented fevereiro 22, 2026 at 23:03 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/941023/Relentless+reboots,+but+runs+fine+once+started.</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/941023</guid>
<pubDate>Sun, 22 Feb 2026 23:03:35 -0700</pubDate>
</item>
<item>
<title><![CDATA[Pulmonetic Systems LTV Series: ventilator ltv 950 not working. power is on completed post test.]]></title>
<description><![CDATA[<p>ventilator ltv 950 not working. power is on completed post test. but on vent check mode always. its not working normally. ventilator enters into vent check mode automatically on switching on.</p>

<p>⟐ Commented fevereiro 09, 2026 at 11:22 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/806133/ventilator+ltv+950+not+working.+power+is+on+completed+post+test.</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/806133</guid>
<pubDate>Mon, 09 Feb 2026 11:22:27 -0700</pubDate>
</item>
<item>
<title><![CDATA[Lowenstein CPAP: Mt touch screen is not responding very well, almost not at all.]]></title>
<description><![CDATA[<p>Top right seems to not work at all, bottom left works ok.</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/936711/Mt+touch+screen+is+not+responding+very+well,+almost+not+at+all.</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/936711</guid>
<pubDate>Mon, 19 Jan 2026 03:47:00 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: Why is my resmed airsense 10 pumping air iregular?]]></title>
<description><![CDATA[<p>My resmed airsense 10 is pumping air in a different pattern then it should. When I breath out it pumps air in.</p>

<p>⟐ Commented janeiro 17, 2026 at 23:36 GMT-7</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/936435/Why+is+my+resmed+airsense+10+pumping+air+iregular</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/936435</guid>
<pubDate>Sat, 17 Jan 2026 23:36:12 -0700</pubDate>
</item>
<item>
<title><![CDATA[Phillips Respironics Dreamstation 2: Blower motor replacement steps]]></title>
<description><![CDATA[<p>Can someone show me step-by-step instructions to remove the blower motor to be replaced with a new one?</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/936417/Blower+motor+replacement+steps</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/936417</guid>
<pubDate>Sat, 17 Jan 2026 11:07:16 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed S9 VPAP Auto: S9 clap machine note : motor pass the …..]]></title>
<description><![CDATA[<p>How to remove a message “motor exids….”</p>

<p>After replacing the motor on s9 machine?</p>]]></description>
<link>https://pt.ifixit.com/Answers/View/932921/S9+clap+machine+note+:+motor+pass+the+%E2%80%A6..</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/932921</guid>
<pubDate>Tue, 30 Dec 2025 06:54:26 -0700</pubDate>
</item>
<item>
<title><![CDATA[ResMed AirSense 10: Resmed AirSense 10 motor SLEEVE?]]></title>
<description><![CDATA[<p>Is there a part number (and do you sell) the Resmed AirSense 10 motor SLEEVE - the blue rubber motor cover shown here:  <a href="https://youtu.be/WM6qBEnmMBI?t=340" rel="nofollow noopener noreferrer">https://youtu.be/WM6qBEnmMBI?t=340</a></p>]]></description>
<link>https://pt.ifixit.com/Answers/View/927919/Resmed+AirSense+10+motor+SLEEVE</link>
<guid isPermaLink="false" >https://pt.ifixit.com/Answers/View/927919</guid>
<pubDate>Tue, 25 Nov 2025 20:52:57 -0700</pubDate>
</item>
</channel>